• Sourcing Solutions
  • Services & Membership
  • Help & Community

Quick Details

  • Place of Origin: Chongqing, China (Mainland)
  • Brand Name: Gold
  • Model Number: GD96
  • Size: 550*510*365mm
  • Weight: 13kg
  • Wavelength Range: 200-900nm

Packaging & Delivery

Packaging Details Export case
Delivery Time 10 days

Features of GD96 Fluorescence Spectrophotometer
 Two operation mode could be chosen: fluorescence intensity and luminous intensity. Fluorescence scanning, kinetic determination and quantity analysis could be done under fluorescence intensity mode.


 365nm exciting wavelength  Raman peak of water in 1 cm quartz fluorescence cuvette S/N≥150.High performance sensitivity simplifies the measurement of low detective sample.


10 stages gain adjustment could be chosen for emission spectrum scanning, including high speed low S/N scanning and precise scanning. Total spectrum scanning could be done in 1 second. With the intelligent pre scanning feature, unknown sample's spectrum information could be detected rapidly. Auto-omission of the influence of scattering peak and harmonic peaks, it ensure the best  measurement parameters and locate the fluorescence emission peak.


 Support off-line mode and on-line mode. Under off-line mode, instrument's computer system offer the fluorescence intensity measurement, concentration direct reading, auto 0 adjustment, auto background subtraction and etc. Under on-line mode, we could use quality and quantity software to control data acquisition and analysis through USB2.0 interface.


 High stable and long life 150W xenon lamp and power source ensure high stable testing and wide range of spectrum.
 The normalized feature for fluorescence value could make different fluorescence's result comparable. 
 Provide optional PC qualitative and quantitative software package with expansible time scanning, wavelength scanning, graphic calculation and storage-access abilities.
 Optional accessories for different measurement, including single hole cell holder, fluorescence sample holder for different features, 200μl micro scale centrifuge tube, micro scale capillary sample holder, semi-auto sample introduction accessories, membrane sample accessories, powder sample accessories, jacket sample accessories and etc.


 Applications and Features of GD96 Fluorescence Spectrophotometer 
 Fluorescence analysis is a high sensitive and high selective sophisticated analytical method. This method can provide information including excitation and emission spectrum, emission light intensity and measurement of life of emission light and polarization fluorescence etc. This method can provide a wide lineal range of working curve. It has becoming an important analytical method in the region of trace analysis. This method has been used in:

 Medical science and clinical analysis Clinical analysis of biological specimen.
 Pharmaceutical science and pharmacology Analysis of natural pharmaceutical products; Quality control of pharmaceuticals and research of pharmaceutical metabolites.
 Biochemistry Analysis of minute quantity of substances in biological body.
Food industry Analysis of minute quantity of constituents in food.
Pollution analysis Atmospheric pollution, environmental testing and food contamination analysis.
Organic and inorganic chemistry:Used in the trace analysis in case of  those substances cannot be determined by absorption spectrophotometry.


Specificatios of GD96 Fluorescence Spectrophotometer
Light source:Hamamatsu 150W Xenon lamp

Exciting optical filters:Interference optical filter
Standard set is equipped with an interference optical filter of central wavelength at 365nm and 10nm bandwidth
An optional interference optical filer of 25mm diameter of wavelength of 250-700 nm can be provided on users demand.
Emission monochromator:C-T diffraction grating(Em 200~900nm,bandwidth 10nm)Wavelength accuracy±1nm Wavelength repeatability ≤0.5nm
Sensitivity:Raman peak of water in 1 cm quartz fluorescence cuvette with
 S/N≥150
Linear measurement(r): ≥0.995
Stability: better than 1.5%/10min
Variation of power source: 220V±22V  50Hz±1Hz
Response time: (0.1-4)s   6 stages adjustable
Fluorescence display value: 0.00-600.00
Data transmission: USB2.0.

Optional Spare Parts and Accessories
Fuses(2A/5A)

200~700nm interference optical filter(φ25mm)
Quartz fluorescence sample cell10mm
Personal computer
Printer cable
Dedicated serial interface printer:See more details in Page 24 of F96PRO Instruction Manual
Dimension  LWH
 550×510×365

Weight(Kg)
 11(N) 13(G).

Transaction History of the Supplier

Below is the information about the supplier's transactions conducted via Alibaba.com. If you require further details regarding the transaction data, please contact the supplier directly.

Transaction Overview

Transactions

Transaction Details

This supplier has completedtransactions with buyers from .

Shipping Destination
Transaction Value
Transaction Date
Email to this supplier
China (Mainland) | Manufacturer, Trading Company
Supplier Assessments:
The supplier supports Trade Assurance – A free service that protects your orders from payment to delivery.
Supplier's Trade Assurance Limit: US $172,000
Learn More